......@@ -3,26 +3,35 @@ from dataprocessing.plottools import *
import matplotlib.pyplot as plt
from plottingtools.config import *
current_EMT = read_timeseries_Modelica( r"C:\Workspace\ReferenceExamples\Modelica\Synchronous Generator\UnitTest_Eremia_3rdOrderModel_Euler_1ms.mat", ["synchronousGenerator_Park.i[1]"])
current_emt_mod = read_timeseries_Modelica(r"\\tsclient\N\Research\German Public\ACS0049_SINERGIEN_bsc\Data\WorkData\SimulationResults\SynchronousGenerator\EMT\UnitTest_Kundur_FullModel_Euler_1us.mat", ["synchronousGenerator_Park.i[1]"]) # Note: both results include only one damper winding in q axis
current_emt_dpsim = read_timeseries_dpsim_real(r"\\tsclient\N\Research\German Public\ACS0049_SINERGIEN_bsc\Data\WorkData\SimulationResults\SynchronousGenerator\EMT\DPsim\UnitTest_FullModel_Trap_1us\data_j.csv")[0]
current_emt_dpsim.values = -current_emt_dpsim.values
# Comparison EMT
figure_id = 1
plt.figure(figure_id, figsize=(12,8))
set_timeseries_labels(current_EMT, ["EMT"])
plot_timeseries(figure_id, current_EMT, plt_color=blue)
set_timeseries_labels(current_emt_mod, ["EMT Modelica"])
plot_timeseries(figure_id, current_emt_mod)
set_timeseries_labels(current_emt_dpsim, "EMT DPsim") # TODO: modelica timeseries needs list element, dpsim timeseries needs string
plot_timeseries(figure_id, current_emt_dpsim, plt_linestyle=':')
plt.xlabel('Zeit [s]')
plt.ylabel('Strom [A]')
plt.show(block=True)
plt.show(block=False)
multi_current_EMT = read_timeseries_Modelica(r"C:\Workspace\ReferenceExamples\Modelica\Synchronous Generator\UnitTest_Eremia_3rdOrderModel_Euler_1ms.mat",[["synchronousGenerator_Park.i[1]"],["synchronousGenerator_Park.i[2]"]])
# Comparison DP
current_dp_mod = read_timeseries_Modelica(r"\\tsclient\N\Research\German Public\ACS0049_SINERGIEN_bsc\Data\WorkData\SimulationResults\SynchronousGenerator\DP\UnitTest_Kundur_FullModel_Euler_1us.mat", ["synchronousGenerator_Park.I[1]"]) # Note: both results include only one damper winding in q axis
current_dp_dpsim = read_timeseries_dpsim_cmpl(r"\\tsclient\N\Research\German Public\ACS0049_SINERGIEN_bsc\Data\WorkData\SimulationResults\SynchronousGenerator\DP\DPsim\UnitTest_FullModel_Trap_1us\data_j.csv")[0]
current_dp_dpsim.values = -current_dp_dpsim.values
current_dpabs_dpsim = current_dp_dpsim.abs(current_dp_dpsim.name + ' abs')
figure_id = 2
plt.figure(figure_id, figsize=(12,8))
set_timeseries_labels(multi_current_EMT, ["Phase a","Phase b","Phase c"])
plot_timeseries(figure_id, multi_current_EMT)
set_timeseries_labels(current_dp_mod, ["DP Modelica"])
plot_timeseries(figure_id, current_dp_mod)
set_timeseries_labels(current_dpabs_dpsim, "DP DPsim") # TODO: modelica timeseries needs list element, dpsim timeseries needs string
plot_timeseries(figure_id, current_dpabs_dpsim, plt_linestyle=':')
plt.xlabel('Zeit [s]')
plt.ylabel('Strom [A]')
plt.show(block=True)