issue309 HeatGeneratorsNew
What is the problem?
The current fast HVAC CHP model can only be used with tabular data which are generated by experiments. Also we want to integrate SOFC and PEM Fuel cells additionally to internal combustion engines (ICEs).
How do we want to solve it? Describe the solution you'd like With a new model we want to allow an alternative method by calculating the efficiency by datasheets or curves.