Changes in HighOrder BuildingModel
The HighOrder BuildingModel has some issues that I would like to change. In accordance with @AnaConstantin we identified the following problems and discussed how to solve it:
What is the problem?
-
AixLib.Building.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.AirExchangePort[4]
must be a vector of 8. - Same model has a package 'Medium' that is not necessary.
- No connection for the heating system "outside" the building model.
- T_Ground must be draged out of the rooms.
Why do we want to solve it?
- Solving these problems enhances the usibility.
How do we want to solve it?
-
1. Use 8 AirExchangePorts -
2. Delete Medium package -
3. Enhance the model by a HeatStarComb (+ Demux) to provide a connection for radiator / floor heating at the "outside" of the building model. Use conditional connections depending of the Boolean withFloorHeating
. -
4. Drag out a heat port for T_Ground. Delete choices for parameter TRY
, since it is only used for T_Ground. -
Additionally some reformatting. -
Revise example model with ideal heaters -
Add example to determine the buildings heat load