citygml-energy issueshttps://git.rwth-aachen.de/energyade/citygml-energy/-/issues2018-12-06T10:43:38+01:00https://git.rwth-aachen.de/energyade/citygml-energy/-/issues/56Building Key Performance Indicators (KPI)2018-12-06T10:43:38+01:00Moritz Robert LausterBuilding Key Performance Indicators (KPI)*Created by: RomainNouvel*
Key Performance Indicators may be important for energy analyses at urban scale, helping for example to understand building consumptions, plan an energy refurbishment strategy, or compare different energy plann...*Created by: RomainNouvel*
Key Performance Indicators may be important for energy analyses at urban scale, helping for example to understand building consumptions, plan an energy refurbishment strategy, or compare different energy planning variants.
They are generally intermediary/final outputs, deduced from other geometry and physical parameters of the 3d city model.
Some useful KPI:
- surfaceAreaToVolumeRatio (index of compacity)
- meanUValue (global envelope insulation level)
- specificPrimaryEnergyDemand (global efficiency of the building)
This issue is a general question: do we want to include some KPIs in our ADE Energy? If yes, they would be parameters of _AbstractBuilding.
backloghttps://git.rwth-aachen.de/energyade/citygml-energy/-/issues/130Simulation results2018-12-06T10:43:38+01:00Moritz Robert LausterSimulation results*Created by: JoachimBenner*
I think the EnergyADE should be able to represent also the **output data of simulation systems**. At the moment, it is possible to include simulated energy demands into an EnergyADE file, but not, e.g., the s...*Created by: JoachimBenner*
I think the EnergyADE should be able to represent also the **output data of simulation systems**. At the moment, it is possible to include simulated energy demands into an EnergyADE file, but not, e.g., the simulated actual temperature of a Thermal Zone.
Because the ADE supports different types of simulations and mutiple simulation systems, it is quite difficult to model arbitrary simulation results. Therefore, I propose to start with a very simple and generic data type **_SimulationData_:** A **text attribute** describing the simulated quantity (e.g. actual temperature) and a **Time Series** with time dependent, scalar data. This data structure can be referenced by every city object (ADE attribute of _CityObject). In future versions of the standard, it might be extended for other types of simulation data, or for supporting references to data bases.https://git.rwth-aachen.de/energyade/citygml-energy/-/issues/141Sensors, Timeseries and measurements requirements2018-12-06T10:43:38+01:00Moritz Robert LausterSensors, Timeseries and measurements requirements*Created by: pascal-schetelat*
This issue is meant to discuss all energy-ade partners needs and use case concerning time series, measurement, sensor and other related concepts.*Created by: pascal-schetelat*
This issue is meant to discuss all energy-ade partners needs and use case concerning time series, measurement, sensor and other related concepts.