Commit f1613254 authored by Moritz Robert Lauster's avatar Moritz Robert Lauster
Browse files

Update Guidelines_EnergyADE.md

parent 22e00cba
......@@ -1477,18 +1477,24 @@ The XML examples below detail the two end-uses of a same building.
System in charge of delivering the energy inside the building, from the place
of energy production to the place of end-use. Power and Thermal distribution
systems are differentiated. They all share a distribution perimeter that is
described by the distribution type.
systems are differentiated. They all share a `distributionPerimeter` that is
described by the `DistributionType` and a `serviceLife` described by the `ServiceLife` type.
### Distribution Type
A list of possible distribution perimeters, e.g. Building, Dwelling, Room.
An enumeration list of dsitribution types that are supplied by `EnergyDistributionSystem`:
- `Building`
- `Dwelling`
- `GroupOfBuildings`
- `Room`
- `Staircase`
- `Storey`
### ThermalDistributionSystem
Type for thermal distribution systems with attributes for circulation
(circulating system or not), the used medium, nominal flow, return and supply
temperatures and thermal losses factor.
Type for thermal distribution systems with attributes for circulation `isCirculation`
(circulating system or not), the used medium of `MediumType`, `nominalFlow`, `returnTemperature` and `supplyTemperature` and `thermalLossesFactor`.
### PowerDistributionSystem
......