......@@ -581,15 +581,30 @@ either inline or by means of xlinks (see example below). In this way,
calculate the heating and cooling demand.
```xml
<!--Example of a ThermalComponent-->
<energy:ThermalComponent gml:id="id_thermalcomponent_1">
<gml:description>Thermal Component 1</gml:description>
<gml:name>Thermal Component 1</gml:name>
<energy:construction xlink:href="#id_construction_1"/>
<energy:area uom="m^2">50.0</energy:area>
<energy:isGroundCoupled>false</energy:isGroundCoupled>
<energy:isSunExposed>true</energy:isSunExposed>
</energy:ThermalComponent>
<!--Example of a Facade with 20% window to wall ratio -->
<energy:ThermalBoundary gml:id="Id_Facade_1">
<energy:thermalBoundaryType>OuterWall</energy:thermalBoundaryType>
<energy:partOf xlink:href="ID_ZONE_1"/>
<energy:composedOf>
<energy:ThermalComponent gml:id="id_Wall_1">
<gml:description>Part of the facade of wall</gml:description>
<energy:construction xlink:href="#id_WallConstruction_1"/>
<energy:area uom="m^2">40.0</energy:area>
<energy:isGroundCoupled>false</energy:isGroundCoupled>
<energy:isSunExposed>true</energy:isSunExposed>
</energy:ThermalComponent>
</energy:composedOf>
<energy:composedOf>
<energy:ThermalComponent gml:id="id_Window_1">
<gml:description>Part of the facade of windows</gml:description>
<energy:construction xlink:href="#id_WindowConstruction_1"/>
<energy:area uom="m^2">10.0</energy:area>
<energy:isGroundCoupled>false</energy:isGroundCoupled>
<energy:isSunExposed>true</energy:isSunExposed>
<energy:relates xlink:href="#opening_window_1"/>
</energy:ThermalComponent>
</energy:composedOf>
</energy:ThermalBoundary>
```
# Temporal Data Module
......@@ -1071,32 +1086,45 @@ comparison with `SolidMaterial`.
![Class diagram of Occupancy Module](fig/class_occupancy.png)
The Occupancy Module contains the detailed characterization of the building
usage, it is related to the rest of the ADE Energy and CityGML model through
the class `UsageZone`. Due to the type of information it allows to store, the
Occupancy Module may be used also for multi-field analysis (socio-economics,
demographics etc.).
usage, it means the people and the facilities. It is related to the rest of the
ADE Energy and CityGML model through the class `UsageZone`.
One building may have several `UsageZone`. Due to the type of information it
allows to store, the Occupancy Module may be used also for multi-field analysis
(socio-economics, demographics etc.).
## Usage zones and building units
### UsageZone
Zone of a building with homogeneous usage type. It is a semantic object, with
an optional geometry (`volumeGeometry`), which may be or not related to a
geometric entity (Building, BuildingPart, Room etc.).
The `UsageZone` is a new object introduced in the Energy ADE to realize
building usage analyses, and in particular to calculate the energy demand
related to occupant-depending end-uses such as domestic hot water, electrical
appliances, cooking etc. When related to the `ThermalZone`, it allows also to
provide the zone usage conditions (e.g. internal gains, HVAC schedules) for the
space heating and cooling demand calculations.
Its usage type is defined by a `usageZoneClass` (corresponding to the CityGML
Code list of the `_AbstractBuilding` attribute class). This zone is operated
with a single heating and cooling set-point temperature schedule
(`heatingSchedule` respectively `coolingSchedule`) and single air ventilation
schedule.
`UsageZone` is a zone of a `Building` (or of a `BuildingPart`) with homogeneous
usage conditions and indoor climate control settings. It is a semantic object,
with an optional geometry (`volumeGeometry`), which may be or not related to a
geometric entity (Building, BuildingPart, Room etc.).
This class inherits from `_CityObject` and may therefore be associated to 1 or
more `EnergyDemand` objects. This class is defined by at least a usage zone
class and a floor area. The building storeys occupied by this UsageZone may be
also indicated by means of the attribute usedFloorNumbers, e.g. with 0
corresponding to the ground floor. Its internalGains attribute corresponds to
the sum of the energy dissipated from the occupants and the facilities inside
the zone.
`UsageZone` is minimally defined by the two mandatory attributes
`usageZoneClass` (its usage type according to the CityGML Code list of the
`_AbstractBuilding` attribute `class`) and `floorArea`. The latter may be
attributed several times to a building, specifying different values for
different `FloorAreaType`.
Its HVAC schedules are characterized by the optional attributes
`heatingSchedule`, `coolingSchedule` and `ventilationSchedule` (respectively
for the heating and cooling set-point temperature schedules, and air
ventilation schedules). Alternatively to the `volumeGeometry` attribute, the
building storeys occupied by this `UsageZone` may be also indicated by means of
the attribute `usedFloors` (0 corresponding to the ground floor).
Its optional `internalGains` attribute corresponds to the sum of the energy
dissipated from the occupants and the facilities inside the zone.
The following XML example describe the modeling of a mixed-usage building.
[Please introduce the photo of the mixed-usage building of Piergiorgio and the
related XML code]
```xml
<!--Example of a UsageZone-->
......@@ -1265,12 +1293,13 @@ vacant).
Each `UsageZone` or `BuildingUnit` object can have one or multiple `Facilities`
objects. Currently there are three types of facilities (DHWFacilities,
ElectricalAppliances and LightingFacilities). Each of them is characterised by
the heatDissipation and the operationSchedule attributes, plus some specific
ones depending on the facility type. In the following, two XML examples are
presented, one for domestic how water facilities and one for electrical
applicances. Please note that the lighting facilities object shares the same
structure and attributes of the ElectricalAppliances.
ElectricalAppliances and LightingFacilities).
Each of them is characterised by the heatDissipation and the operationSchedule
attributes, plus some specific ones depending on the facility type.
In the following, two XML examples are presented, one for domestic how water
facilities and one for electrical applicances.
Please note that the lighting facilities object shares the same structure and
attributes of the ElectricalAppliances.
```xml
<!--Example of a DHWFacilities object-->
......@@ -1323,23 +1352,87 @@ structure and attributes of the ElectricalAppliances.
![Class diagram of Energy System Module](fig/class_EnergySystem.png)
The Energy System Module is a module of the ADE Energy which contains
information concerning the energy forms (energy demand, supply, sources) and
the energy systems (conversion, distribution and storage systems). It is
arranged around one central `EnergyDemand` object.
The Energy System Module contains the energy forms (energy demand and sources)
and energy systems (conversion, distribution and storage systems) to realize
energy demand and supply analyses.
It allows also to calculate $CO_2$ emissions or Primary energy balances.
It is related to the Energy ADE and CityGML model through the object
`EnergyDemand`, which can be related to any `_CityObject`.
The `EnergyConversionSystems` may be additionally related to the
`_AbstractBuilding` and `_BoundarySurface` where, respectively on which, they
are installed.
The Energy System Module follows a "star structure", with the
`EnergyDistributionSystem`, `_StorageSystem` and `EnergyConversionSystem` all
related to the central object `EnergyDemand`, defined for different end-uses
(e.g. space heating, electrical appliances) and acquisition methods (e.g.
measurements, simulation).
## Energy amounts and types
### EnergyDemand
Useful energy required to satisfy a specific end use, such as heating, cooling,
domestic hot water etc. Beside its `EndUseType`, this object is characterized
its `energyAmount` (time-depending energy demand value) and its maximum yearly
load (`maximumLoad`) used for the sizing of the energy systems.
The `EnergyDemand` is the central object of the Energy System Module.
Every `_CityObject` (typically `ADE:_AbstractBuilding`, `ThermalZone`,
`UsageZone` and `BuildingUnit`) may have one or more `EnergyDemand`.
It is the useful energy required to satisfy the specific end-use (e.g. space
heating, space cooling, domestic hot water) of a given object (`_CityObject` to
which it relates).
Beside its attribute `endUse`, this object is characterized by its
`energyAmount` (time-depending energy demand values) and its maximum
yearly load (`maximumLoad`) used for the sizing of the energy systems.
Every `_CityObject` (typically `_AbstractBuilding`, `ThermalZone`, `UsageZone`
and `BuildingUnit`) may have one or more `EnergyDemand`, related to its
different `endUseType`, and possibly to different `acquisitionMethod` and
`sources` (both attributes of the `TimeValueProperties` defining the time
series `energyAmount`) such as "measurements", "simulations" etc.
The XML examples below detail the two end-uses of a same building.
```xml
<!--Building characterized with its Domestic hot water and electrical appliances demands-->
<bldg:Building>
<energy:energyDemands>
<energy:EnergyDemand>
<energy:endUse>DomesticHotWater</energy:endUse>
<energy:energyAmount>
<energy:IrregularTimeSeries>
<gml:description>DHW demand of Mr X for year 2016</gml:description>
<energy:variableProperties>
<energy:TimeValuesProperties>
<energy:acquisitionMethod>Measurements</energy:acquisitionMethod>
<energy:source>Company X, year 2016</energy:source>
</energy:TimeValuesProperties>
</energy:variableProperties>
<energy:uom uom="kWh"/>
<!-- here come the values of the time series -->
</energy:IrregularTimeSeries>
</energy:energyAmount>
<energy:maximumLoad uom="kW">8.0</energy:maximumLoad>
</energy:EnergyDemand>
</energy:energyDemands>
<energy:energyDemands>
<energy:EnergyDemand>
<energy:endUse>ElectricalAppliances</energy:endUse>
<energy:energyAmount>
<energy:RegularTimeSeriesFile>
<gml:description>Simulated electrical demand of Mr X for typical year</gml:description>
<energy:variableProperties>
<energy:TimeValuesProperties>
<energy:acquisitionMethod>Simulated</energy:acquisitionMethod>
<energy:source>Research Institut Y</energy:source>
</energy:TimeValuesProperties>
</energy:variableProperties>
<!-- here come the file reading information -->
</energy:IrregularTimeSeries>
</energy:energyAmount>
<energy:maximumLoad uom="kW">5.2</energy:maximumLoad>
</energy:EnergyDemand>
</energy:energyDemands>
</bldg:Building>
```
### EndUseType
List of possible end uses as cooking, space heating and ventilation.
......@@ -1410,7 +1503,7 @@ battery technology.
System converting an energy source into the energy necessary to satisfy the
`EnergyDemand` (or to feed the networks).
Energy conversion systems have common parameters: efficiency indicator, nominal
`EnergyConversionSystem` have common parameters: efficiency indicator, nominal
installed power, nominal efficiency (in reference to an efficiency indicator),
year of manufacture, name of the model, a serial number, a reference to product
or installation documents and optionally refurbishment measures. They may be
......