......@@ -32,32 +32,16 @@ This document is intended to explain the characteristics and purposes of each mo
![Class diagram of Building Physics Module](fig/class_geometry.png)
This module contains the thermal building objects required for building thermal
modelling (e.g. calculation of space heating and space cooling demands):
`ThermalZone`, `ThermalBoundary`, `ThermalComponent`. These thermal building
objects are linked to the CityGML building objects through its
`_AbstractBuilding`, `_BoundarySurface`, `_Opening` classes, which are extended
with Energy ADE attributes.
The `ThermalZone`, which represents the spatial unit for heating and cooling
demand calculation, is the central object of this Building Physics Module. A
Building may have several `ThermalZone`, for instance in the case of
mixed-usage building, or to distinguish rooms or zones with different solar
gains and/or thermal behaviour.
If occupied, a `ThermalZone` must be related to at less 1 `UsageZone`, which
contains the usage boundary conditions for the heating and cooling demand
calculation (see Occupancy Module). `ThermalZone` may be related to several
`UsageZone` for simplified modelling of mixed-usage space, in which case the
usage boundary conditions of the `UsageZone` should be aggregated or weighted
according with their floorArea.
Main purpose of this module is building thermal modeling (e.g. calculation of space heating and space cooling demands).
Thus, it extends the existing CityGML objects `_AbstractBuilding`, `_BoundarySurface`and `_Opening` with energy-related attributes, and define new thermal building objects `ThermalZone`, `ThermalBoundary`, respectively `ThermalComponent` related to them.
The `ThermalZone `is the unit volume for heating and cooling demand calculation. A Building may have several `ThermalZone`, for instance in the case of mixed-usage building, or to distinguish rooms or zones with different orientations (i.e. solar gains) and/or thermal behaviour.
These `ThermalZone` objects are separated from each other and from the outside
by `ThermalBoundary` objects. These `ThermalBoundary` objects may or not
correspond to the CityGML `_BoundarySurface`. However, every `ThermalBoundary`
delimiting the `ThermalZone` from outside must be related (`correspondsTo`)
with a `_BoundarySurface`, in order to consider the `globalSolarIrradiance`
incident on `_BoundarySurface` in the heating and cooling calculations.
These `ThermalZone` objects are separated from each other and from the outside by `ThermalBoundary` objects. These `ThermalBoundary` objects may or not correspond to the CityGML `_BoundarySurface`. To count the `globalSolarIrradiance` incident on `_BoundarySurface` in the building energy balance, every `ThermalBoundary` delimiting the `ThermalZone` from outside should however be related (relation `correspondsTo`) with a `_BoundarySurface`.
If occupied, a `ThermalZone` must be related to at less 1 `UsageZone`, which contains the usage boundary conditions required for the heating and cooling demand calculation (see Occupancy Module). One `ThermalZone` may be related to several `UsageZone` for simplified modelling of mixed-usage space, in which case the usage boundary conditions of the `UsageZone` should be aggregated or weighted
according with their floorArea.