Skip to content
Snippets Groups Projects

Compare revisions

Changes are shown as if the source revision was being merged into the target revision. Learn more about comparing revisions.

Source

Select target project
No results found
Select Git revision
  • main
1 result

Target

Select target project
  • florian.weiss/calorimetry_laboratory
  • philipp.schmidt2/calorimetry_laboratory
  • paul.bobrinskoy/calorimetry_laboratory
  • vincent.jestaedt/calorimetry_laboratory
  • elias.rausch/calorimetry_laboratory
  • dennis.dibbern/calorimetry_laboratory
  • bianca.beer/calorimetry_laboratory
  • luca.sommer/calorimetry_laboratory
  • jannik.hoffmann/calorimetry_laboratory
  • adrian.gabel1/calorimetry_laboratory
  • erwin.durasow/calorimetry_laboratory
  • ole.quiring/calorimetry_laboratory
  • david.buening/calorimetry_laboratory
  • daniel.burgos/calorimetry_laboratory
  • malte.kramp/calorimetry_laboratory
  • vladimir.pascari/calorimetry_laboratory
  • fst-tuda/public/lehre/calorimetry_laboratory
  • nilay.kuslugil/calorimetry_laboratory
  • christoph.froehlich/calorimetry_laboratory
  • lucas.gomiero/calorimetry_laboratory
  • patrick.schell/calorimetry_laboratory
  • noel.schwibus/calorimetry_laboratory
  • gregor.komora/calorimetry-laboratory-komora
  • thomas.gruber/calorimetry_laboratory
  • leo.mensler/calorimetry_laboratory
  • paul_konrad.braun/calorimetry-laboratory-paul
  • jakob.maurer/calorimetry_laboratory
  • jakob.knoblach/calorimetry_laboratory
  • marius.stumpe/calorimetry_laboratory
  • diogo.fernandes_costa/calorimetry_laboratory
  • hiab.berhane/calorimetry_laboratory
  • zidane.buermann/calorimetry_laboratory
  • maximilian.gross1/calorimetry_laboratory
  • tahsin.ahmad/calorimetry_laboratory
  • santiago.ramirez_saldana/calorimetry_laboratory
  • moritz.roth/calorimetry_laboratory
  • noah.waltmann/calorimetry_laboratory
  • keanu.engel/calorimetry_laboratory
  • noah.michel1/calorimetry_laboratory
  • julie.kickstein/calorimetry_laboratory
  • maurizio.fell/calorimetry_laboratory
  • junghyun.seo/calorimetry-laboratory
  • paul.zuendel/calorimetry_laboratory
  • alexander.neubauer/calorimetry_laboratory
  • constantin.messingfeld/calorimetry_laboratory
  • malte.lesche/calorimetry_laboratory
  • felix.meyners/calorimetry_laboratory
  • henri.sprickmann/calorimetry_laboratory
  • zineb.karri/calorimetry_laboratory
  • ilhan_mert.dumlupinar/calorimetry_laboratory
  • tim.ostendorf/calorimetry_laboratory
  • lukas.ripp/calorimetry_laboratory
  • amen.bouzouraa/calorimetry_laboratory
  • ammon.wuendisch/calorimetry_laboratory
  • louis.randa/calorimetry_laboratory
  • mattheo.beyer/calorimetry_laboratory
  • pascal.grym/calorimetry_laboratory
  • bryan.lauren/calorimetry_laboratory
  • hani.husseini/calorimetry_laboratory
  • jonas.dissinger/calorimetry_laboratory
  • zhibo.zhao/calorimetry_laboratory
  • buesra.akkaya/calorimetry_laboratory
  • philipp.bojunga/calorimetry_laboratory
  • soner.elbudak/calorimetry_laboratory
  • pascal.schraut/calorimetry_laboratory
  • alicia.sachs/calorimetry_laboratory
  • tarish.kalra/calorimetry_laboratory
  • lilly.laubenheimer/calorimetry_laboratory
  • simon.peters/calorimetry_laboratory
  • tobias.erdmann/calorimetry_laboratory
  • philip.mahouttchi-hosseini/calorimetry_laboratory
  • yixing.tao/calorimetry_laboratory
  • konstantinos.boiadjiev/calorimetry_laboratory
  • ibrahim.alsaleh/calorimetry_laboratory
  • adonay.johannes/calorimetry_laboratory
  • sotiris.giovannis/calorimetry-laboratory-giovanns
  • manuel.kaster/calorimetry_laboratory
  • samuel.neidert/calorimetry_laboratory
  • rafi.noordin/calorimetry-laboratory-noordin-rafi
  • robert.schaefer1/calorimetry_laboratory
  • artashes.manukyan/calorimetry_laboratory
  • tolga.guelec/calorimetry_laboratory
  • bob.putz/calorimetry_laboratory
  • konrad.winkhaus/calorimetry-laboratory-kw
  • calvin.weide/calorimetry_laboratory
  • julius.damm/calorimetry_laboratory
  • louis.senff/calorimetry_laboratory
  • boris.dasgupta/calorimetry_laboratory
  • leon.herz/calorimetry_laboratory
  • marc.dobner/calorimetry_laboratory
  • benjamin.gross/calorimetry_laboratory
  • leon.dawkins/calorimetry_laboratory
  • nico.sebastian/calorimetry_laboratory
  • francisco.flores/calorimetry_laboratory
  • luca_tobias.nuecker/calorimetry_laboratory
95 results
Select Git revision
  • main
1 result
Show changes
Showing
with 347 additions and 31 deletions
{
"JSON": {
"ID": "1ee5ec03-7e64-6071-8ca3-98dbab0a7719",
"label": "",
"comment": "UUID6 is used"
},
"sensor": {
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "3cf9e3818fb8",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
"type": "absolute",
"unit": "degree_celsius"
}
}
}
{
"JSON": {
"ID": "1ee5ec04-30cd-678f-a64b-0ce7544ef5e8",
"label": "",
"comment": "UUID6 is used"
},
"sensor": {
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "3c01f095b066",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
"type": "absolute",
"unit": "degree_celsius"
}
}
}
{
"JSON": {
"ID": "1ee5ec04-c845-69e2-853a-25c11543466f",
"label": "",
"comment": "UUID6 is used"
},
"sensor": {
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "3c01f095d465",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
"type": "absolute",
"unit": "degree_celsius"
}
}
}
{
"JSON": {
"ID": "1ee5ec05-4aea-68f6-ad82-53b16fffae49",
"label": "",
"comment": "UUID6 is used"
},
"sensor": {
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "3c25f6490937",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
"type": "absolute",
"unit": "degree_celsius"
}
}
}
......@@ -51,9 +51,9 @@
"name": "temperature_hot_water_bath",
"comment": ""
},
"xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx": {
"1ee87a9e-b060-62d2-8fe3-41db0cd25253": {
"type": "probe",
"name": "probe_PDCXXX",
"name": "probe_PDC028",
"comment": ""
}
}
......
## This file is for git to be able to version control empty folders, you can ignore this file, it only helps us to keep the structure of the template. ##
\ No newline at end of file
......@@ -13,7 +13,7 @@
"source": {
"type": "adjustable laboratory power supply",
"model": "DPPS-32-20",
"manufacturer": "Voltcraft",
"manufacturer": "VOLTCRAFT",
"power": "640 Watt",
"technology": "clocked power supply",
"voltage": "1...32 V",
......@@ -22,4 +22,4 @@
}
}
}
}
\ No newline at end of file
}
......@@ -17,14 +17,14 @@
"medium": {
"type": "water",
"mass": {
"value": XXXXX,
"value": 400,
"unit": "gramm",
"accuracy": {
"value": XXXXX,
"value": 0,
"type": "absolute",
"unit": "gramm"
}
}
}
}
}
\ No newline at end of file
}
......@@ -5,13 +5,13 @@
"comment": "UUID6 is used"
},
"group": {
"number": "Group_XX",
"member": [
"member01",
"member02",
"member03"
"number": "Laborversuch_Group37",
"author": [
"Diogo Fernandes Costa",
"Zidane Bürmann",
"Santiago Ramirez Saldana"
],
"experiment": "calorimetry",
"testrig_number": "TR_X"
"testrig_number": "1"
}
}
\ No newline at end of file
}
......@@ -9,8 +9,8 @@
"type": "single_board_computer",
"manufacturer": "Raspberry Pi Foundation",
"model": "Raspberry Pi 4 Model B Rev. 1.5",
"serial": "10000000483672da",
"serial": "10000000dbd18662",
"operating_system": "Raspberry Pi OS",
"comment": "to get model and serial number put this code in the terminal: cat /proc/cpuinfo"
}
}
\ No newline at end of file
}
{
"JSON": {
"ID": "1ee57b2e-d878-640b-b947-b68f86e0e1c9",
"label": "PDC003",
"comment": "UUID6 is used"
},
"probe": {
"material": "Edelstahl",
"mass": {
"value": 610,
"unit": "gramm",
"uncertainty": {
"value": 1,
"type": "absolut",
"unit": "gramm"
}
},
"dimensions": {
"height": {
"value": 40,
"unit": "millimeter"
},
"diameter": {
"value": 60,
"unit": "millimeter"
},
"volume": {
"value": 80570,
"unit": "cubic millimeter"
}
}
}
}
\ No newline at end of file
{
"JSON": {
"ID": "1ee57b38-1b08-63da-8b38-63a271236a0b",
"label": "PDC012",
"comment": "UUID6 is used"
},
"probe": {
"material": "Messing",
"mass": {
"value": 667,
"unit": "gramm",
"uncertainty": {
"value": 1,
"type": "absolut",
"unit": "gramm"
}
},
"dimensions": {
"height": {
"value": 40,
"unit": "millimeter"
},
"diameter": {
"value": 60,
"unit": "millimeter"
},
"volume": {
"value": 80570,
"unit": "cubic millimeter"
}
}
}
}
\ No newline at end of file
{
"JSON": {
"ID": "1ee7d44b-07b6-6af8-adbe-d5e4818c9942",
"label": "PDC028",
"comment": "UUID6 is used"
},
"probe": {
"material": "PA_6_6",
"mass": {
"value": 92,
"unit": "gramm",
"uncertainty": {
"value": 1,
"type": "absolut",
"unit": "gramm"
}
},
"dimensions": {
"height": {
"value": 40,
"unit": "millimeter"
},
"diameter": {
"value": 60,
"unit": "millimeter"
},
"volume": {
"value": 80570,
"unit": "cubic millimeter"
}
}
}
}
\ No newline at end of file
......@@ -8,12 +8,12 @@
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "xxxxxxxxxxxx",
"serial": "3c01f0956007",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "xxx"
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
......@@ -21,4 +21,4 @@
"unit": "degree_celsius"
}
}
}
\ No newline at end of file
}
......@@ -8,12 +8,12 @@
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "xxxxxxxxxxxx",
"serial": "3cf9e3818fb8",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "xxx"
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
......@@ -21,4 +21,4 @@
"unit": "degree_celsius"
}
}
}
\ No newline at end of file
}
......@@ -8,12 +8,12 @@
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "xxxxxxxxxxxx",
"serial": "3c01f095b066",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "xxx"
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
......@@ -21,4 +21,4 @@
"unit": "degree_celsius"
}
}
}
\ No newline at end of file
}
......@@ -8,12 +8,12 @@
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "xxxxxxxxxxxx",
"serial": "3c01f095d465",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "xxx"
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
......@@ -21,4 +21,4 @@
"unit": "degree_celsius"
}
}
}
\ No newline at end of file
}
......@@ -8,12 +8,12 @@
"name": "Temperature_Sensor",
"type": "DS18B20",
"manufacturer": "keyestudio",
"serial": "xxxxxxxxxxxx",
"serial": "3c25f6490937",
"comment": "",
"range": {
"min": -55,
"max": 125,
"units": "xxx"
"units": "degree_celsius"
},
"accuracy": {
"value": 0.5,
......@@ -21,4 +21,4 @@
"unit": "degree_celsius"
}
}
}
\ No newline at end of file
}
{
"JSON": {
"ID": "1ee5ec2a-3557-61fd-88c5-45f35110e2ad",
"label": "",
"comment": "UUID6 is used"
},
"comment": "this setup is used to measure the specific heat capacity of a probe",
"setup": {
"1ee5ec0a-1830-63f5-ac3e-6f8ce4468546": {
"type": "group_info",
"name": "group_info",
"comment": ""
},
"1ee5ec0d-e77c-68b7-90f7-2e33485ff91c": {
"type": "instrument",
"name": "raspberry_pi",
"comment": ""
},
"1ee5ec0c-0b57-68cd-9d39-c9b7e9b18753": {
"type": "calorimeter",
"name": "calorimeter",
"comment": ""
},
"1ee21750-5282-63bc-86e9-b4de622ee43e": {
"type": "actor",
"name": "sous_vide heater",
"comment": "this heater is used to heat the water in the hot water bath for the samples"
},
"1ee5ec00-4a00-68a1-bb1e-873c2dd4dbde": {
"type": "sensor",
"name": "temperature_calorimeter_1",
"comment": ""
},
"1ee5ec03-7e64-6071-8ca3-98dbab0a7719": {
"type": "sensor",
"name": "temperature_calorimeter_2",
"comment": ""
},
"1ee5ec04-30cd-678f-a64b-0ce7544ef5e8": {
"type": "sensor",
"name": "temperature_calorimeter_3",
"comment": ""
},
"1ee5ec04-c845-69e2-853a-25c11543466f": {
"type": "sensor",
"name": "temperature_environment",
"comment": ""
},
"1ee5ec05-4aea-68f6-ad82-53b16fffae49": {
"type": "sensor",
"name": "temperature_hot_water_bath",
"comment": ""
},
"1ee87a91-8f66-67a2-9cf8-36ce3b859240": {
"type": "probe",
"name": "probe_PDC003",
"comment": ""
}
}
}
\ No newline at end of file
{
"JSON": {
"ID": "1ee5ec2a-9a12-6199-af26-20cb6ca9e9ca",
"label": "",
"comment": "UUID6 is used"
},
"comment": "this setup is used to measure the specific heat capacity of a probe",
"setup": {
"1ee5ec0a-1830-63f5-ac3e-6f8ce4468546": {
"type": "group_info",
"name": "group_info",
"comment": ""
},
"1ee5ec0d-e77c-68b7-90f7-2e33485ff91c": {
"type": "instrument",
"name": "raspberry_pi",
"comment": ""
},
"1ee5ec0c-0b57-68cd-9d39-c9b7e9b18753": {
"type": "calorimeter",
"name": "calorimeter",
"comment": ""
},
"1ee21750-5282-63bc-86e9-b4de622ee43e": {
"type": "actor",
"name": "sous_vide heater",
"comment": "this heater is used to heat the water in the hot water bath for the samples"
},
"1ee5ec00-4a00-68a1-bb1e-873c2dd4dbde": {
"type": "sensor",
"name": "temperature_calorimeter_1",
"comment": ""
},
"1ee5ec03-7e64-6071-8ca3-98dbab0a7719": {
"type": "sensor",
"name": "temperature_calorimeter_2",
"comment": ""
},
"1ee5ec04-30cd-678f-a64b-0ce7544ef5e8": {
"type": "sensor",
"name": "temperature_calorimeter_3",
"comment": ""
},
"1ee5ec04-c845-69e2-853a-25c11543466f": {
"type": "sensor",
"name": "temperature_environment",
"comment": ""
},
"1ee5ec05-4aea-68f6-ad82-53b16fffae49": {
"type": "sensor",
"name": "temperature_hot_water_bath",
"comment": ""
},
"1ee87a9d-9978-6070-b6c2-f287dc7964ab": {
"type": "probe",
"name": "probe_PDC012",
"comment": ""
}
}
}
\ No newline at end of file